Low Frequency Electric and Magnetic fields (EMF)
However, for household products the EMF testing is covered under the LVD and is a required test standard for CE marking. In the US, restrictions are found from the FCC.
Basic limits for EMF from Household products according to EN 62233:
Basic restrictions for electric, magnetic and electromagnetic fields
(0 Hz to 300 GHz)
Frequency Range |
Magnetic flux density mT |
Current density mA/m2 r.m.s |
Whole body average SAR W/kg |
Localized SAR (head and trunk) W/kg |
Localized SAR Limbs W/kg |
Power density, S W/m2 |
0 Hz |
40 |
|||||
>0-1 Hz |
8 |
|||||
1-4 Hz |
8/f |
|||||
4 -1000 Hz |
2 |
|||||
1000 Hz -100 Hz |
f/500 |
|||||
100 kHz- 10 MHz |
f/500 |
0,08 |
2 |
4 |
||
10 MHz – 10 GHz |
0,08 |
2 |
4 |
|||
10 -300 GHz |
10 |
|||||
f is the frequency in HZ |
||||||
Contact Nemko
Please phone or send us your request in the form below, and we will contact you as soon as possible. Let us know your purpose and we will find the right person to call you back.


The Nemko Direct Program for more challenging international approvals – they truly are a fast and competitive alternative