Low Frequency Electric and Magnetic fields (EMF)

The EU Recommendation (1999/519/EC) was introduced in 1999. It provides basic restrictions to protect the general public from EMF exposure.

The EMF at Work Directive (2004/40/EC) protects workers from the risks arising from the exposure to EMF in the workplace. It is not a directive required for CE marking; rather it is part of the EU Occupational Health and Safety regulations.

However, for household products the EMF testing is covered under the LVD and is a required test standard for CE marking.  In the US, restrictions are found from the FCC.

Basic limits for EMF from Household products according to EN 62233:

 

Basic restrictions for electric, magnetic and electromagnetic fields

(0 Hz to 300 GHz)

 


Frequency Range

Magnetic flux density


mT

Current density


mA/m2
r.m.s

Whole body average
SAR


W/kg

Localized SAR
(head and trunk)

W/kg

Localized
SAR
Limbs


W/kg

Power density,
S


W/m2

0 Hz

40






>0-1 Hz


8





1-4 Hz


8/f





4 -1000 Hz


2





1000 Hz -100 Hz


f/500





100 kHz- 10 MHz


f/500

0,08

2

4


10 MHz – 10 GHz



0,08

2

4


10 -300 GHz






10

f is the frequency in HZ