Skip to content
Search our site  
    August 4, 2021

    EN 300 328 V2.2.2 becomes mandatory on 6 August 2021

    Are you Ready? written on the road

    The Internet of Things (IoT) transformation is not an intangible of the future possibilities, but rather a reality with billions of devices deployed each year. With billions of devices entering the market every year, it’s a wonder that our devices can connect and link so effectively while sharing the same spectrum. As the Internet of Things continues to grow, so does the potential for signal interference between products utilizing a 2.4 GHz radio frequency.

    In order to comply with these market requirements for electrical and electronic products with radio transmitters and receivers, manufacturers, importers, and distributors are required to strictly adhere to the EU Radio Equipment Directive 2014/53/EU and UK Radio Equipment Regulation 2017, including compliance with the related harmonized standards and designated standards lists. And one key standard whose deadline for establishing compliance is quickly approaching is EN 300 328 V2.2.2.

    Compliance with EN 300 328 V2.2.2 will become mandatory for radio products within its scope from 6 August 2021 onward. This new version replaces EN 300 328 V2.1.1 which was originally published 13 January 2017 for transmission systems operating in the license free 2.4 GHz band.

    The 2.4 GHz band is used for technologies such as 2.4 GHz WLAN, Bluetooth, ZigBee, and more. Products that have not established compliance with EN 300 328 V2.2.2 after 5 August 2021 cannot continue to be placed on the market.


    What are important changes to note in EN 300 328 V2.2.2?


    Assessment type / section Important changes to note:
    Antenna Types
    (Section 4.2.4)
    New addition from previous version. Specifies that dedicated antennas must be assessed in combination with equipment to meet requirements.

    Accumulated Transmit Time, Frequency Occupation and Hopping Sequence Conducted Measurements
    (Section 5.4.4.2.1)

    Test methods have been revised in the sixth step in order to indicate the use of a peak detector rather than Root Mean Square (RMS). Additionally, the number of sweep points is defined as ~400/Occupied Channel Bandwidth (MHz). This number may be increased in situations where there are overlapping channels.

    RF Output Power — Conducted Measurements
    (Section 5.4.2.2.1.2)

    The test method for Radio Frequency (RF) Output Power requires a fast power sensor with minimum sensitivity of -40 dBm is included in the new version.

    Power Spectral Density Conducted Measurements (Section 5.4.3.2.1)

    There are two options for power density test methods. Option 1, equipment with continuous and non-continuous transmissions, is now required to use maximum TX-sequence time in place of channel occupancy time within the formula for determining sweep time for non-adaptive, non-continuous transmission equipment.

    Option 2, equipment with continuous transmission capabilities, is revised from 2x the nominal bandwidth for determining frequency spans to at least 2x the Occupied Channel Bandwidth.

    Presentation of Equipment (Sections 2.2 and 5.3.4)

    These sections reference ETSI EG 203 367 Guide for the application of harmonized standards that cover 3.1b and 3.2 Directive 2014/53/EU for multi-radio and combined radio and non-radio equipment. The existing content has been removed where it was addressed by the previous standard.

    Received Category
    (Section 4.2.3)

    This section redefines receiver categories in order to address all combinations of equipment types and power levels.

    Received Blocking Limits (Sections 4.3.1.12.4 and 4.3.2.11.4)

    Receiver blocking parameters are redefined across all receiver categories. The blocking signal power has increased, however the wanted signal power from companion devices has also been revised. These changes may not result in more stringent requirements than the first version, but conformance must be evaluated.

    Receiver Blocking Performance Data
    (Sections 4.3.1.12.3 and 4.3.2.11.3)

    A new reference to Frame Error Rate (FER) is made. The option for the manufacturer to declare alternative performance criteria has been removed. However, for equipment that does not support a PER or FER test, the minimum performance criteria must be that there is no loss of the wireless transmission functions that are necessary for the intended use of the equipment.

    Receiver Blocking Test Method (Section 5.4.11.2)

    This section has been revised in correlation to the changes made in the receiver blocking limits and parameters. There are additional measurement methods available, including extended steps to address any non-compliance issues.

    Transmitter Unwanted Emissions in the Out-of-Band Domain
    (Section 5.4.8.2.1)

    The test method has been revised to specify the measurement mode as Time Domain Power, as well as a revision regarding sweep mode from continuous to single. The maximum number of sweep points has increased to 30,000.

    Transmitted Unwanted Emissions in the Spurious Domain — Limits
    (Sections 4.3.1.10.3 and 4.3.2.9.3)

    The limits of frequency range from 694-862 MHz have been revised to -36 dBm. These less stringent limits align with CEPT ERC Recommendation 74-01, which is based on the transition from analog to digital and the resulting spectrum allocation.


    Who will be affected by this change?

    Manufacturers of products that are supporting technologies such as Bluetooth, Wi-Fi, ZigBee, and other wideband and frequency-hopping (FHSS) data transmission equipment that is capable of operating in the band 2400 — 2483.5 MHz frequency band will be affected. This is not only applicable to those implementing chipset solutions but also those incorporating modules provided by third parties.

    This will affect products being placed on the market in the European Union, as well as the United Kingdom

    How will manufacturers demonstrate compliance?

    In order to demonstrate compliance with the updated standard, manufacturers must conduct a review of existing test reports in order to evaluate the changes as they relate to specific products. Limited testing must be performed to demonstrate compliance with the latest requirements, with all proper documentation made in a test report that is held in the manufacturer’s technical construction file.

    If an EU Notified Body Type Examination Certification or UK Approved Body Type Examination Certification was previously obtained or currently desired, the manufacturer must complete an application for Modification Certification. The Declaration of Conformity must be updated to reflect compliance with EN 300 328 V2.2.2.

    It’s also important to note that any manufacturer who incorporates a third-party module and uses third party Declaration of Conformity documentation and test reports in the technical file must request to be issued the latest documentation from their provider.

    Any noncompliant products placed on the market on or after 6 August 2021 may result in a variety of enforcement actions and penalties against the manufacturer to enforce compliance with EN 300 328 V2.2.2, including withdrawal of products from the market, sanctions, and other fines.


    The Benefits of working with Nemko
    1. By choosing Nemko as your market access partner, you will be working with experienced processionals focused on delivery via the optimal route to product compliance and testing as well as can guide you towards the right path for certification.
    2. Nemko provides a fast turnaround time, helping to get your products to market in as little time as possible.
    3. Nemko test reports provides well-known readability & easy access to any marketplace. 

     

    For more information about how Nemko India can help with your product testing requirements, please contact us or write to us at India@nemko.com

    Anshuman Dash

    Anshuman Dash is a product compliance specialist & marketing professional having extensive years of experience in many standards & regulatory requirements. He has a Bachelor Degree in Engineering from "Institute of Technical Education & Research" , Bhubaneswar and currently pursuing Masters. Along with International...

    Other posts you might be interested in